(480) 804-1227
You Are Here: Home > AC01282-10

AC01282-10
Fiber Cable, OFS fiber cable Duplex 200/230 µm Step-Index General purpose, Zipcord, 2.5 mm PVC jacket

AC01282-10 Fiber Cable, OFS fiber cable Duplex 200/230 µm Step-Index
Manufacturer: OFS
Manufacturer's PDF Data Sheet
Transmission graph
RoHS Certification: No

  Structure
Core Material Silica
Cladding Material Polymer
Core Refractive Index 1.452 @ 850 nm
Refractive Index Profile Step-index
Numerical Aperture .37
Number of Fibers 2
Unit Value
Core Diameter µm 200 ± 4
Cladding Diameter µm 220 - 230
Approximate Weight g/m 11
  Jacket
Material and Color PVC/ Orange
Indication on Jacket None
Unit Value
Sub-unit Diameter mm 2.5 ± 0.2
Outer Diameter mm 2.5 x 5.2
Fiber Tensile Strength N 378
  Applications: Indoor Industrial

Spool Length: n/a

Sectional view of duplex fiber cable 12 times actual size: orange outer jacket, aramid yarn, buffer and fiber inner circles

Sectional View


Part Number: AC01282-10
Price (per meter)
Quantity

 
 1 to 99 $ 3.45 
 100 to 199 $ 2.88 
 200 to 2,499 $ 2.30 
 2,500 to 9,999 $ 2.25 
 10,000 to 24,999 $ 2.16 
25,000+ $ 2.03 

No set spool lengths

 Performance Criteria for Acceptance
and/or
[ Test Conditions ]
Unit Value
Maximum
Rating
Storage Temperature No Physical Deterioration
[ in a Dry Atmosphere ]
° C -40 to +80
Operating Temperature No Deterioration in Optical Properties
[ in a Dry Atmosphere ]
° C -20 to +80
No Deterioration in Optical Properties
[ under 95% RH condition ]
° C -20 to +80
Optical
Properties
Transmission Loss (650 nm Collimated Light)
[ 25°C 50% RH ]
dB/m < 6 dB/km @ 850 nm
Transmission Loss
under 95% RH
(650 nm Collimated Light)
[ Operating Temperature ]
dB/m
Mechanical
Characteristics
Minimum Bend Radius Loss Increment <0.5 dB
[ A Quarter Bend ]
mm 38
Repeated Bending
Endurance
Loss Increment <1 dB
[ Conforms to JIS C 6861 ]
Times
Tensile Strength Tensile Force at 5%
[ Elongation: Conforms to JIS C. 6861 ]
N 378
Twisting Strength Loss Increment <1 dB
[ Sample Length: 1 m Tensile Force: 4.9 N ]
Times
Impact Strength Loss Increment <1 dB
[ Sample Length: 1 m JIS C 6861 ]
N.m