(480) 804-1227
You Are Here: Home > Optical Fiber/Cable > Eska™ Products > Eska™ Fiber Cable > GHEL4002-OR

GHEL4002-OR
Eska™ Premier Polyethylene Buffered & Hytrel Sheathed Fiber Cord

GHEL4002-OR Eska™ Premier Polyethylene Buffered & Hytrel Sheathed Fiber Cord
Manufacturer: Mitsubishi Rayon Co. LTD.
Manufacturer's PDF Data Sheet
Transmission graph
RoHS Certification: No

  Structure
Core Material Polymethyl-Methacrylate Resin
Cladding Material Fluorinated Polymer
Core Refractive Index 1.49
Refractive Index Profile Step-index
Numerical Aperture .50
Number of Fibers 2
Unit Value
Core Diameter µm 920 - 1040
Cladding Diameter µm 940 - 1060
Approximate Weight g/m 21
  Jacket
Material and Color PE (black)/ Hytrel (orange)
Indication on Jacket Pink strip on one of internal pair; Eska™ Premier on outer jacket
Unit Value
Sub-unit Diameter mm 2.2 x 4.3 ± .07
Outer Diameter mm 4 x 5.5 ± .2
Fiber Tensile Strength N 195
  Applications: Indoors/outdoors where high chemical resistance and durability are required in outdoor UV light conditions such as outdoor boom truck operation.

Spool Length: 500 m

Sectional View


Part Number: GHEL4002-OR
Price (per spool)
Quantity

 
 1 to 2 $ 3,830.00 
 3 to 9 $ 3,574.67 
 10 to 19 $ 2,945.00 
 20 to 39 $ 2,838.55 
 40 to 99 $ 2,771.76 
100+ $ 2,677.27 


Part Number: 81 0141
Price (per meter)
Quantity

 
$10.70 

 Performance Criteria for Acceptance
and/or
[ Test Conditions ]
Unit Value
Maximum
Rating
Storage Temperature No Physical Deterioration
[ in a Dry Atmosphere ]
° C - 40 ~+ 85
Operating Temperature No Deterioration in Optical Properties
[ in a Dry Atmosphere ]
° C - 40 ~ +85
No Deterioration in Optical Properties
[ under 95% RH condition ]
° C + 60 Max.
Optical
Properties
Transmission Loss (650 nm Collimated Light)
[ 25°C 50% RH ]
dB/m .19 Max.
Transmission Loss
under 95% RH
(650 nm Collimated Light)
[ Operating Temperature ]
dB/m .21 Max.
Mechanical
Characteristics
Minimum Bend Radius Loss Increment <0.5 dB
[ A Quarter Bend ]
mm 40
Repeated Bending
Endurance
Loss Increment <1 dB
[ Conforms to JIS C 6861 ]
Times 1,000
Tensile Strength Tensile Force at 5%
[ Elongation: Conforms to JIS C. 6861 ]
N 195
Twisting Strength Loss Increment <1 dB
[ Sample Length: 1 m Tensile Force: 4.9 N ]
Times 5
Impact Strength Loss Increment <1 dB
[ Sample Length: 1 m JIS C 6861 ]
N.m 0.4