SMCK-1000P

High NA, 19-core Fused Multi-Core Simplex Cable, Polyethylene Jacket 19-core High NA, 1.0 mm Fused Multi-Core Simplex Cable, 2.2 mm OD Polyethylene Jacket


SMCK-1000P High NA, 19-core Fused Multi-Core Simplex Cable, Polyethylene Jacket

Sectional View

Application: Industrial simplex networking and sensor applications requiring higher bandwidth, or a small bend radii is required than standard solid core POF is rated for.

Manufacturer: Asahi Kasei

Part Number: SMCK-1000P



Part Number: SMCK-1000P
Price (500 m per spool)

 
 1 to 2 $ 1,615.38 
 3 to 4 $ 1,550.77 
 5 to 9 $ 1,346.15 
 10 to 19 $ 1,305.77 
 20 to 24 $ 1,250.00 
 25+ Call for Quote
 
Quantity


  Feet to Meters Length Converter
Feet to Meters Converter
Type a value in the Feet field
to convert to Meters:



Meters:

  Box Size (mm):
  Gross Weight* (kg): 0
 
Estimated LT: 3-4 weeks

  Structure
Core Material PMMA
Cladding Material Fluorinated Polymer
Core Refractive Index 1.49
Refractive Index Profile Step
Numerical Aperture 0.6
Number of Fibers 1
 
Unit Value
Cladding Diameter μm 920 - 1080
  Buffer/Jacket
Material and Color Polyethylene (black)
Indication on Jacket None
 
Unit Value
Outer Diameter mm 2.2 ± .07
Fiber Tensile Strength N 80
Performance Criteria for Acceptance
and/or
[ Test Conditions ]
Unit Value
Maximum
Rating
Storage Temperature No Physical Deterioration
[ in a Dry Atmosphere ]
° C - 55° ~ 85° C
Operating Temperature No Deterioration in Optical Properties
[ in a Dry Atmosphere ]
° C - 55° ~ 85° C
No Deterioration in Optical Properties
[ under 95% RH condition ]
° C N/R
Optical
Properties
Transmission Loss (650 nm Collimated Light)
[ 25°C 50% RH ]
dB/m 0.5 Max.
Transmission Loss
under 95% RH
(650 nm Collimated Light)
[ Operating Temperature ]
dB/m N/R
Mechanical
Characteristics
Minimum Bend Radius Loss Increment <0.5 dB
[ A Quarter Bend ]
mm 2
Tensile Strength Tensile Force at 5%
[ Elongation: Conforms to JIS C. 6861 ]
N 80
Twisting Strength Loss Increment <1 dB
[ Sample Length: 1 m Tensile Force: 4.9 N ]
Times N/R
Impact Strength Loss Increment <1 dB
[ Sample Length: 1 m JIS C 6861 ]
N.m N/R
Copyright 2000 - 2024, All Rights Reserved Industrial Fiber Optics